Everything about Alternating Current totally explained
An
alternating current (
AC) is an
electrical current whose
magnitude and direction vary cyclically, as opposed to
direct current, whose direction remains constant. The usual
waveform of an
AC power circuit is a
sine wave, as this results in the most efficient transmission of energy. However in certain applications different waveforms are used, such as triangular or square waves.
Used generically, AC refers to the form in which
electricity is delivered to businesses and residences. However,
audio and
radio signals carried on electrical
wire are also examples of alternating current. In these applications, an important goal is often the recovery of
information encoded (or
modulated) onto the AC signal.
History
William Stanley, Jr. designed one of the first practical devices to transfer AC power efficiently between isolated circuits. Using pairs of coils wound on a common iron core, his design, called an
induction coil, was an early
transformer. The AC power system system used today developed rapidly after 1886, and includes key concepts by
Nikola Tesla, who subsequently sold his patent to
George Westinghouse.
Lucien Gaulard,
John Dixon Gibbs,
Carl Wilhelm Siemens and others contributed subsequently to this field. AC systems overcame the limitations of the
direct current system used by
Thomas Edison to distribute electricity efficiently over long distances.
The first modern commercial power plant using three-phase alternating current was at the Mill Creek hydroelectric plant near
Redlands, California in 1893 designed by
Almirian Decker. Decker's design incorporated 10,000 volt three-phase transmission and established the standards for the complete system of generation, transmission and motors used today.
Alternating current circuit theory evolved rapidly in the latter part of the 19th and early 20th century. Notable contributors to the theoretical basis of alternating current calculations include
Charles Steinmetz,
James Clerk Maxwell,
Oliver Heaviside, and many others. Calculations in unbalanced three-phase systems were simplified by the
symmetrical components methods discussed by
Charles Legeyt Fortescue in 1918.
Transmission, distribution, and domestic power supply
AC power can be increased or decreased in voltage with a
transformer. Use of a higher voltage leads to significantly more efficient transmission of power. The power losses in a conductor are a product of the square of the current and the
resistance of the conductor, described by the formula
. This means that when transmitting a fixed power on a given wire, if the current is doubled, the power loss will be four times greater.
Since the power transmitted is equal to the product of the current, the voltage and the
cosine of the phase difference φ (
), the same amount of power can be transmitted with a lower current by increasing the voltage. Therefore it's advantageous when transmitting large amounts of power to distribute the power with high voltages (often hundreds of kilovolts).
However, high voltages also have disadvantages, the main ones being the increased insulation required, and generally increased difficulty in their safe handling. In a
power plant, power is generated at a convenient voltage for the design of a
generator, and then stepped up to a high voltage for transmission. Near the loads, the transmission voltage is stepped down to the voltages used by equipment. Consumer voltages vary depending on the country and size of load, but generally motors and lighting are built to use up to a few hundred volts between phases.
The utilization voltage delivered to equipment such as lighting and motor loads is standardized, with an allowable range of voltage over which equipment is expected to operate. Standard power utilization voltages and percentage tolerance vary in the different
mains power systems found in the world.
Modern
high-voltage, direct-current electric power transmission systems contrast with the more common alternating-current systems as a means for the bulk transmission of electrical power over long distances. HVDC systems tend to be more expensive and less efficient than transformers. Transmission with high voltage direct current wasn't feasible when
Edison,
Westinghouse and
Tesla were designing their power systems, since there was then no way to economically convert AC power to DC and back again at the necessary voltages.
Three-phase electrical generation is very common. Three separate coils in the generator
stator are physically offset by an angle of 120° to each other. Three current waveforms are produced that are equal in magnitude and 120°
out of phase to each other.
If the load on a three-phase system is balanced equally among the phases, no current flows through the
neutral point. Even in the worst-case unbalanced (linear) load, the neutral current won't exceed the highest of the phase currents. It is noteworthy that non-linear loads (for example computers) may require an oversized neutral bus and neutral conductor in the upstream distribution panel to handle
harmonics. Harmonics can cause neutral conductor current levels to exceed that of one or all phase conductors.
For three-phase at utilization voltages a four-wire system is often used. When stepping down three-phase, a transformer with a Delta primary and a Star secondary is often used so there's no need for a neutral on the supply side.
For smaller customers (just how small varies by country and age of the installation) only a
single phase and the neutral or two phases and the neutral are taken to the property. For larger installations all three phases and the neutral are taken to the main distribution panel. From the three-phase main panel, both single and three-phase circuits may lead off.
Three-wire single phase systems, with a single centre-tapped transformer giving two live conductors, is a common distribution scheme for residential and small commercial buildings in North America. This arrangement is sometimes incorrectly referred to as "two phase". A similar method is used for a different reason on construction sites in the UK. Small power tools and lighting are supposed to be supplied by a local center-tapped transformer with a voltage of 55V between each power conductor and the earth. This significantly reduces the risk of
electric shock in the event that one of the live conductors becomes exposed through an equipment fault whilst still allowing a reasonable voltage for running the tools.
A
third wire, called the bond wire, is often connected between non-current carrying metal enclosures and earth ground. This conductor provides protection from electrical shock due to accidental contact of circuit conductors with the metal chassis of portable appliances and tools. Bonding all non-current carrying metal parts into one complete system ensures there's always a low impedance path to ground sufficient to carry any fault current for as long as it takes for the system to clear the fault. This low impedance path allows the maximum amount of fault current to flow, causing the overcurrent protection device (Breakers, fuses) to trip or burn out as quickly as possible, returning the electrical system to a safe state. All bond wires are bonded to ground at the main service panel, as is the Neutral/Identified Conductor if present.
AC power supply frequencies
The
frequency of the electrical system varies by country; most electric power is generated at either 50 or 60 Hz. See
List of countries with mains power plugs, voltages and frequencies. Some countries have a mixture of 50 Hz and 60 Hz supplies, notably Japan.
A low frequency eases the design of low speed electric motors, particularly for hoisting, crushing and rolling applications, and commutator-type
traction motors for applications such as
railways, but also causes a noticeable flicker in incandescent lighting and objectionable flicker of
fluorescent lamps. 16⅔ Hz power is still used in some European rail systems, such as in
Austria,
Germany,
Norway,
Sweden and
Switzerland. The use of lower frequencies also provided the advantage of lower impedance losses, which are proportional to frequency. The original Niagara Falls generators were built to produce 25 Hz power, as a compromise between low frequency for traction and heavy induction motors, while still allowing incandescent lighting to operate (although with noticeable flicker); most of the 25 Hz residential and commercial customers for Niagara Falls power were converted to 60 Hz by the late 1950's, although some 25 Hz industrial customers still existed as of the start of the 21st century.
Off-shore,military, textile industry, marine, computer
mainframe, aircraft, and spacecraft applications sometimes use 400 Hz, for benefits of reduced weight of apparatus or higher motor speeds.
Effects at high frequencies
A direct, constant current flows uniformly throughout the cross-section of the (uniform) wire that carries it. With alternating current of any frequency, the current is forced towards the outer surface of the wire, and away from the center. This is because an
electric charge which accelerates (as is the case of an alternating current)
radiates electromagnetic waves, and materials of high
conductivity (the metal which makes up the wire) don't allow propagation of electromagnetic waves. This phenomenon is called
skin effect.
At very high frequencies the current no longer flows
in the wire, but effectively flows
on the surface of the wire, within a thickness of a few
skin depths. The skin depth is the thickness at which the current density is reduced by 63%. Even at relatively low frequencies used for high power transmission (50–60 Hz), non-uniform distribution of current still occurs in sufficiently thick
conductors. For example, the skin depth of a copper conductor is approximately 8.57 mm at 60 Hz, so high current conductors are usually hollow to reduce their mass and cost.
Since the current tends to flow in the periphery of conductors, the effective cross-section of the conductor is reduced. This increases the effective
AC resistance of the conductor, since resistance is inversely proportional to the cross-sectional area in which the current actually flows. The AC resistance often is many times higher than the
DC resistance, causing a much higher energy loss due to
ohmic heating (also called I
2R loss).
Techniques for reducing AC resistance
For low to medium frequencies, conductors can be divided into stranded wires, each insulated from one other, and the individual strands specially arranged to change their relative position within the conductor bundle. Wire constructed using this technique is called
Litz wire. This measure helps to partially mitigate skin effect by forcing more equal current flow throughout the total cross section of the stranded conductors. Litz wire is used for making high
Q inductors, reducing losses in flexible conductors carrying very high currents at power frequencies, and in the windings of devices carrying higher
radio frequency current (up to hundreds of kilohertz), such as switch-mode
power supplies and
radio frequency transformers.
Techniques for reducing radiation loss
As written above, an alternating current is made of
electric charge under periodic
acceleration, which causes
radiation of
electromagnetic waves. Energy that's radiated represents a loss. Depending on the frequency, different techniques are used to minimize the loss due to radiation.
Twisted pairs
At frequencies up to about 1 GHz, wires are paired together in cabling to form a
twisted pair in order to reduce losses due to
electromagnetic radiation and
inductive coupling. A twisted pair must be used with a balanced signalling system, where the two wires carry equal but opposite currents. The result is that each wire in the twisted pair radiates a signal that's effectively cancelled by the other wire, resulting in almost no electromagnetic radiation.
Coaxial cables
At frequencies above 1 GHz, unshielded wires of practical dimensions lose too much energy to radiation, so
coaxial cables are used instead. A coaxial cable has a conductive wire inside a conductive tube. The current flowing on the inner conductor is equal and opposite to the current flowing on the inner surface of the outer tube. This causes the electromagnetic field to be completely contained within the tube, and (ideally) no energy is radiated or coupled outside the tube. Coaxial cables have acceptably small losses for frequencies up to about 20 GHz. For
microwave frequencies greater than 20 GHz, the
dielectric losses (due mainly to the
dissipation factor of the dielectric layer which separates the inner wire from the outer tube) become too large, making
waveguides a more efficient medium for transmitting energy.
Waveguides
Waveguides are similar to coax cables, as both consist of tubes, with the biggest difference being that the waveguide has no inner conductor. Waveguides can have any arbitrary cross section, but rectangular cross sections are the most common. With waveguides, the energy is no longer carried by an
electric current, but by a
guided electromagnetic field. Waveguides have dimensions comparable to the
wavelength of the alternating current to be transmitted, so they're only feasible at microwave frequencies.
Fiber optics
At frequencies greater than 200 GHz, waveguide dimensions become impractically small, and the
ohmic losses in the waveguide walls become large. Instead,
fiber optics, which are a form of dielectric waveguides, can be used. For such frequencies, the concepts of voltages and currents are no longer used.
Mathematics of AC voltages
Alternating currents are accompanied (or caused) by alternating voltages. In English the initialism AC is commonly and somewhat confusingly used for both. An AC voltage
v can be described mathematically as a
function of time by the following equation:
» of the 240 V AC is double that, at about 679 V.
Further reading
Willam A. Meyers, History and Reflections on the Way Things Were: Mill Creek Power Plant - Making History with AC, IEEE Power Engineering Review, February 1997, Pages 22-24Further Information
Get more info on 'Alternating Current'.
|
External Link Exchanges
Do you know how hard it is to get a link from a large encyclopaedia? Well we're different and will prove it. To get a link from us just add the following HTML to your site on a relevant page:
<a href="http://alternating_current.totallyexplained.com">Alternating current Totally Explained</a>
Then simply click through this link from your web page. Our crawlers will verify your link, extract the title of your web page and instantly add a link back to it. If you like you can remove the words Totally Explained and embed the link in article text.
As long as your link remains in place, we'll keep our link to you right here. Please play fair - our crawlers are watching. Your site must be closely related to this one's topic. Any kind of spamming, dubious practises or removing the link will result in your link from us being dropped and, potentially, your whole site being banned. |